Published August 1, 1977 | Version v1
Journal article

Preliminary results on the time resolution of a plastic scintillator neutron counter of large area for neutrons of 16 MeV

  • 1. Trieste Univ. (Italy). Istituto di Fisica

Description

The time resolution measurements of a plastic scintillator neutron detector of large area (200x15 cm2) are reported. For neutrons of 16 MeV, obtained with the T(d,n)4He reaction and a solid Ti-T target, the corrected time resolution turns out to be equal to 670 ps, for a proton threshold energy of 10 MeV. (Auth.)

Additional details

Identifiers

Publishing Information

Journal Title
Nuclear Instruments and Methods
Journal Volume
144
Journal Issue
3
Series
Nucl. Instrum. Methods.
Journal Page Range
479-484
ISSN
0029-554X

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent