Published January 1992 | Version v1
Report Open

Determination of radon levels in Mexico City

Description

The study of the determination of radon levels in the houses room in Mexico City is part of the project Emanometry of the radon. To carry out this study, the passive method was used, which consists of: thin film dosemeter of cellulose nitrate, container of the same one and spark accountant. The method is based on the mensurations of exhibition of the number of marks of alpha track is of the open type and it allows to average the radon activity along several weeks and it presents low concentrations. This study was carried out in 4 periods of exhibition of 3 months each one. (Author)

Availability note (English)

Available from INIS in electronic form

Files

37057561.pdf

Files (468.0 kB)

Name Size Download all
md5:110276e3c8ce2626432a17904c59091a
468.0 kB Preview Download

Additional details

Additional titles

Original title (Spanish)
Determinacion de niveles de radon en la Ciudad de Mexico

Publishing Information

Imprint Pagination
12 p.
Report number
IA--92-301

Optional Information

Secondary number(s)
INIS-MX-RI--0060