Published August 2008 | Version v1
Journal article

An analytical calculation of the peak efficiency for cylindrical sources perpendicular to the detector axis in gamma-ray spectrometry

  • 1. Autoridad Regulatoria Nuclear, Laboratorio de Espectrometria Gamma-CTBTO, Av. Del Libertador 8250, C1429BNP Buenos Aires (Argentina)

Description

An analytical expression for the so-called full-energy peak efficiency ε(E) for cylindrical source with perpendicular axis to an HPGe detector is derived, using point-source measurements. The formula covers different measuring distances, matrix compositions, densities and gamma-ray energies; the only assumption is that the radioactivity is homogeneously distributed within the source. The term for the photon self-attenuation is included in the calculation. Measurements were made using three different sized cylindrical sources of 241Am, 57Co, 137Cs, 54Mn, and 60Co with corresponding peaks of 59.5, 122, 662, 835, 1173, and 1332 keV, respectively, and one measurement of radioactive waste drum for 662, 1173, and 1332 keV

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2007.12.007

Additional details

Identifiers

DOI
10.1016/j.apradiso.2007.12.007;
PII
S0969-8043(07)00391-0;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
66
Journal Issue
8
Journal Page Range
p. 1123-1127
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Copyright
Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.