Published 1991 | Version v1
Book

Improvement of JACS code system

  • 1. 9699476JP
  • 2. CRC Research Institute, Inc., Chiba (Japan)

Description

A new MGCL (Multi-Group Constants Library) library with P3-scattering data, named MGCL-J3, has been produced from the newest evaluated nuclear data library in Japan. MULTI-KENO-II, the updated version of MULTI-KENO, can treat triangular array system, and calculate neutron scattering by hydrogen nuclide exactly. For a series of UO2F2 solution critical experiment, calculated keff's by MULTI-KENO-II with MGCL-J3 are closer to the measured value 1.0 than those by KENO-IV with MGCL-B-IV. This is due to the difference of thermal v-value of 235U and order of Legendre polynomials, and the more exact way of calculating neutron scattering by hydrogen nuclide in MULTI-KENO-II. (Author)

Part of:
ICNC '91: international conference on nuclear criticality safety

Additional details

Publishing Information

Publisher
AEA Technology.
Imprint Place
Winfrith (United Kingdom)
Imprint Title
ICNC '91: international conference on nuclear criticality safety
Imprint Pagination
395 p.
Journal Page Range
v 1. p. IV.36-IV.44.

Conference

Title
international conference on nuclear criticality safety.
Acronym
ICNC '91
Dates
9-13 Sep 1991.
Place
Oxford (United Kingdom).

INIS

Optional Information

Notes
Imprint:Conference published in 3 v.