Published 2000
| Version v1
Book
The initial investigation of radiation dose rate at X-ray department and patients treating thyroid by I-131 at nuclear medicine department
Description
Survey meter NSM 150 Fuji with detector Geiger Muller has been used to assess for average annual exposure dose which affect radiographer ≤ 2 mSv per year, the staff involved with Fluoroscopy ≤ 19 mSv per year. Dose rate in waiting area of patient is a range from 0.2 to 0.8 μSv/h. Patients who have been treated by radioiodine, may be only discharged when the remaining activity is 400.2 ±368.8 MBq. Radioactivity of I-131 and Tc-99m in the sewage system of hospital is 0.4x10-11 Ci/l. (author)
Additional details
Additional titles
- Original title (Vietnamese)
- Tuyen tap bao cao Hoi nghi toan quoc lan thu ba vat ly va ky thuat hat nhan
Publishing Information
- Publisher
- Publisher of Sciences and Techniques
- Imprint Place
- Hanoi (Viet Nam)
- Imprint Title
- Proceedings of the Third National Conference on Nuclear Physics and Techniques
- Imprint Pagination
- 670 p.
- Journal Page Range
- p. 557-560
INIS
- Country of Publication
- Viet Nam
- Country of Input or Organization
- Viet Nam
- INIS RN
- 33011153
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- DOSE RATES; IODINE 131; OCCUPATIONAL SAFETY; PATIENTS; RADIOLOGY; RADIOTHERAPY; STATISTICAL DATA; WHOLE-BODY IRRADIATION
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; DATA; DAYS LIVING RADIOISOTOPES; EXTERNAL IRRADIATION; INFORMATION; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; IRRADIATION; ISOTOPES; MEDICINE; NUCLEAR MEDICINE; NUCLEI; NUMERICAL DATA; ODD-EVEN NUCLEI; RADIOISOTOPES; RADIOLOGY; SAFETY; THERAPY
Optional Information
- Notes
- 6 refs, 5 tabs Imprint:Tuyen tap bao cao Hoi nghi toan quoc lan thu ba vat ly va ky thuat hat nhan