Published 2000 | Version v1
Book

The initial investigation of radiation dose rate at X-ray department and patients treating thyroid by I-131 at nuclear medicine department

  • 1. Cho Ray Hospital (Viet Nam)

Description

Survey meter NSM 150 Fuji with detector Geiger Muller has been used to assess for average annual exposure dose which affect radiographer ≤ 2 mSv per year, the staff involved with Fluoroscopy ≤ 19 mSv per year. Dose rate in waiting area of patient is a range from 0.2 to 0.8 μSv/h. Patients who have been treated by radioiodine, may be only discharged when the remaining activity is 400.2 ±368.8 MBq. Radioactivity of I-131 and Tc-99m in the sewage system of hospital is 0.4x10-11 Ci/l. (author)

Part of:
Proceedings of the Third National Conference on Nuclear Physics and Techniques

Additional details

Additional titles

Original title (Vietnamese)
Tuyen tap bao cao Hoi nghi toan quoc lan thu ba vat ly va ky thuat hat nhan

Publishing Information

Publisher
Publisher of Sciences and Techniques
Imprint Place
Hanoi (Viet Nam)
Imprint Title
Proceedings of the Third National Conference on Nuclear Physics and Techniques
Imprint Pagination
670 p.
Journal Page Range
p. 557-560

Optional Information

Notes
6 refs, 5 tabs Imprint:Tuyen tap bao cao Hoi nghi toan quoc lan thu ba vat ly va ky thuat hat nhan