MO-AB-BRA-09: Temporally Realistic Manipulation a 4D Biomechanical Lung Phantom for Evaluation of Simultaneous Registration and Segmentation
- 1. McGill University, Montreal, QC (Canada)
Description
Purpose: To produce multi-modality compatible, realistic datasets for the joint evaluation of segmentation and registration with a reliable ground truth using a 4D biomechanical lung phantom. The further development of a computer controlled air flow system for recreation of real patient breathing patterns is incorporated for additional evaluation of motion prediction algorithms. Methods: A pair of preserved porcine lungs was pneumatically manipulated using an in-house computer controlled respirator. The respirator consisted of a set of bellows actuated by a 186 W computer controlled industrial motor. Patient breathing traces were recorded using a respiratory bellows belt during CT simulation and input into a control program incorporating a proportional-integral-derivative (PID) feedback controller in LabVIEW. Mock tumors were created using dual compartment vacuum sealed sea sponges. 65% iohexol,a gadolinium-based contrast agent and 18F-FDG were used to produce contrast and thus determine a segmentation ground truth. The intensity distributions of the compartments were then digitally matched for the final dataset. A bifurcation tracking pipeline provided a registration ground truth using the bronchi of the lung. The lungs were scanned using a GE Discovery-ST PET/CT scanner and a Phillips Panorama 0.23T MRI using a T1 weighted 3D fast field echo (FFE) protocol. Results: The standard deviation of the error between the patient breathing trace and the encoder feedback from the respirator was found to be ±4.2%. Bifurcation tracking error using CT (0.97×0.97×3.27 mm3 resolution) was found to be sub-voxel up to 7.8 cm displacement for human lungs and less than 1.32 voxel widths in any axis up to 2.3 cm for the porcine lungs. Conclusion: An MRI/PET/CT compatible anatomically and temporally realistic swine lung phantom was developed for the evaluation of simultaneous registration and segmentation algorithms. With the addition of custom software and mock tumors, the entire package offers ground truths for benchmarking performance with high fidelity
Additional details
Identifiers
- DOI
- 10.1118/1.4925279;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 42
- Journal Issue
- 6
- Journal Page Range
- vp.
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47126414
- Subject category
- S60: APPLIED LIFE SCIENCES; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- AIR FLOW; ALGORITHMS; DATASETS; EVALUATION; FLUORINE 18; GROUND TRUTH MEASUREMENTS; IOHEXOL; LUNGS; NEOPLASMS; NMR IMAGING; PATIENTS; PHANTOMS; POSITRON COMPUTED TOMOGRAPHY; RESPIRATION; SWINE; TUNGSTEN 186
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BODY; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; DIAGNOSTIC TECHNIQUES; DISEASES; DOCUMENT TYPES; DOMESTIC ANIMALS; EMISSION COMPUTED TOMOGRAPHY; EVEN-EVEN NUCLEI; FLUID FLOW; FLUORINE ISOTOPES; GAS FLOW; HEAVY NUCLEI; HOURS LIVING RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LIGHT NUCLEI; MAMMALS; MATHEMATICAL LOGIC; MOCKUP; NANOSECONDS LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; ORGANS; RADIOISOTOPES; RESPIRATORY SYSTEM; STABLE ISOTOPES; STRUCTURAL MODELS; TOMOGRAPHY; TUNGSTEN ISOTOPES; VERTEBRATES
Optional Information
- Notes
- (c) 2015 American Association of Physicists in Medicine