Published February 1977 | Version v1
Journal article

The relationship between void size and positron lifetime in neutron irradiated molybdenum

  • 1. Danmarks Tekniske Hoejskole, Lyngby. Applied Physics Lab. 2
  • 2. UKAEA Research Group, Harwell. Metallurgy Div.

Description

A number of molybdenum specimens, each containing a characteristic void size spectrum, have been subjected to positron lifetime measurements. Although the average void size varied in radius from 9 A to 45 A the long positron lifetime in the specimens was remarkably constant with tau2 = 465 +- 5 ps. Therefore for the range of void sizes examined, this parameter appears to be independent of the void size. (orig.)

Abstract (German)

Eine Anzahl Molybdaen-Proben mit jeweils charakteristischer Groessenverteilung der Leerstellen wurde mit der Methode der Positronvernichtung untersucht. Obwohl der mittlere Leerstellenradius Werte zwischen 9 A und 45 A hatte, blieb die lange Positron-Lebensdauer in der Probe tau2 = 465 +- 5 ps bemerkenswert konstant. Im Bereich der untersuchten Leerstellenradien ist daher dieser Parameter unabhaengig von der Groesse der Leerstellen. (orig.)

Additional details

Publishing Information

Journal Title
Appl. Phys.
Journal Volume
12
Journal Issue
2
Series
Appl. Phys.
Journal Page Range
187-189

Optional Information

Notes
2 figs.; 1 tab.; 10 refs.