Influence of cross-contamination on PET values for simultaneous emission/transmission acquisition using the mask technique
- 1. Nagoya Univ. (Japan). Hospital
Description
For the quantitative accuracy of simultaneous emission/transmission (SET) acquisition using the mask technique, we confirmed the contamination of photons that spilled over from the transmission source into the emission data, and evaluated the influence of decay correction with different half-lives of the transmission source and emission source. First, to confirm the contamination of photons from the transmission source, SET scans were performed with a cold phantom and blank status in the field of the gantry. Second, to evaluate the quantitative accuracy of the PET values obtained by the decay correction, serial scanning with SET and conventional scanning were carried out with the same frame time. All of the data were reconstructed with the decay correction based on the same scan start time, and counts of ROI on the reconstructed images were evaluated. For SET acquisition, contamination of photons from the transmission source into the emission data due to the scattered photons, which were from the object and spillover fraction through the mask window, was shown. The intensity of this contamination was dependent on the activity of the transmission source. Quantitative accuracy was affected by the decay correction of the SET data. The effect was emphasized by increasing the emission activity or reducing the transmission activity. It is suggested that the effect of attenuation correction is based on the transmission data, which are subtracted from the emission data. These characteristics should be carefully considered for the quantitative estimation of SET acquisition. (author)
Additional details
Publishing Information
- Journal Title
- Nippon Hoshasen Gijutsu Gakkai Zasshi
- Journal Volume
- 57
- Journal Issue
- 5
- Journal Page Range
- p. 565-572
- ISSN
- 0369-4305
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 32033302
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COMPARATIVE EVALUATIONS; FLUORINE 18; GALLIUM 68; GERMANIUM 68; IMAGE PROCESSING; PHANTOMS; POSITRON COMPUTED TOMOGRAPHY; SCATTERING; UPTAKE
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; COMPUTERIZED TOMOGRAPHY; DAYS LIVING RADIOISOTOPES; DIAGNOSTIC TECHNIQUES; ELECTRON CAPTURE RADIOISOTOPES; EMISSION COMPUTED TOMOGRAPHY; EVALUATION; EVEN-EVEN NUCLEI; FLUORINE ISOTOPES; GALLIUM ISOTOPES; GERMANIUM ISOTOPES; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LIGHT NUCLEI; MOCKUP; NANOSEC LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; PROCESSING; RADIOISOTOPES; STRUCTURAL MODELS; TOMOGRAPHY