Shielding calculations. Optimization vs. Paradigms
- 1. Centro de Proteccion e Higiene de las Radiaciones, La Habana (Cuba)
Description
Many radiation shielding barriers in Cuba have been designed according to the criterion of Maxi-mum Projected Dose Rates. This fact has created the paradigm of low dose rates. Because of this, dose rate levels greater than units of Sv.h-1 would be considered unacceptable by many specialists, regardless of the real exposure times. Nowadays many shielding barriers are being designed using dose constraints in real exposure times. Behind the new barriers, dose rates could be notably greater than those behind the traditional ones, and it does not imply inadequate designs or constructive errors. In this work were obtained significant differences in dose rate levels and shield-ing thicknesses calculated by both methods for some typical installations. The work concludes that real exposure time approach is more adequate in order to optimise Radiation Protection, although this method should be carefully applied
Additional details
Additional titles
- Original title (Spanish)
- Calculos de blindajes, optimizacion vs. Paradigmas
Publishing Information
- Journal Title
- Nucleus (Havana)
- Journal Issue
- no.37
- Journal Page Range
- p. 30-33
- ISSN
- 0864-084X
INIS
- Country of Publication
- Cuba
- Country of Input or Organization
- Cuba
- INIS RN
- 36074153
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- COMPUTER CALCULATIONS; EXPOSURE CHAMBERS; LOW DOSE IRRADIATION; RADIATION DOSES; RADIATION PROTECTION; SHIELDING
- Descriptors DEC
- DOSES; IRRADIATION