Published January 15, 1988 | Version v1
Journal article

Time resolution of a large area planar spark counter

  • 1. Nara Women's Univ. (Japan). Dept. of Physics
  • 2. National Lab. for High Energy Physics, Oho, Ibaraki (Japan)

Description

A planar spark counter of size 1.0 m x 0.1 m has been developed and tested. The constituent elements are a semiconductive glass anode and a window float-cast glass cathode coated by vacuum-deposited copper. The distance between electrodes is 200 μm. A single counter time resolution of 61 ps was achieved with cosmic rays. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
263
Journal Issue
2/3
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
381-386
ISSN
0168-9002
CODEN
NIMAE

INIS