An experimental study on the influential factors of flow measurement with coriolis mass flowmeter
Creators
- 1. Korea Research Institute of Standards and Science, Taejon (Korea, Republic of)
Description
Coriolis Mass Flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity standard reference material whose viscosities are 1, 20 and, 67 mm2/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air. It shows 1∼1.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied
Additional details
Publishing Information
- Journal Title
- Transactions of the Korean Society of Mechanical Engineers. B
- Journal Volume
- 27
- Journal Issue
- 12
- Series
- 9 refs, 11 figs, 1 tab
- Journal Page Range
- p. 1699-1707
- ISSN
- 1226-4881
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36085867
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- CALIBRATION; CORIOLIS FORCE; FLOW RATE; FLOWMETERS; PIPELINES; PUMPS; TUBES; VELOCITY; VISCOSITY
- Descriptors DEC
- EQUIPMENT; MEASURING INSTRUMENTS; METERS