Published 1991 | Version v1
Journal article

Response and background study of various PADC materials

  • 1. Paul Scherrer Inst. (PSI), Villigen (Switzerland)

Description

The results of response and background studies of polyallyl diglycol carbonate (PADC) as a neutron detector are presented. Commercially available polymeric detectors supplied by five different manufacturers were used. For each type/thickness of material, two or three sheets were sampled. Each sheet was divided into six equal areas and from each, 3 or 4 background and 2 sensitivity detectors were taken and the total of 512 samples were tested. The sensitivity was determined for normally incident 252Cf neutrons. The highest sensitivity of 0.2 cm-2.μSv-1 with the lowest average background of about 150 μSv for a single sheet was found. The minimum detectable dose equivalent (three standard deviations) obtained was 153 μSv. (author)

Additional details

Additional titles

Augmented title (English)
Detection of fast neutron's by means of polallyl diglycol carbonate

Publishing Information

Journal Title
Nuclear Tracks and Radiation Measurements
Journal Volume
19
Journal Issue
1-4
Series
Nucl. Tracks Radiat. Meas.
Journal Page Range
445-448
ISSN
0735-245X
CODEN
NTRMD

Conference

Title
15. international conference on particle tracks in solids.
Dates
3-7 Sep 1990.
Place
Marburg (Germany).