Prospective intraindividual comparison between respiratory-triggered balanced steady-state free precession and breath-hold gradient-echo and time-of-flight magnetic resonance imaging for assessment of portal and hepatic veins
Creators
- 1. University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland)
- 2. University Hospital Zurich, Department of Medical Radiology, Zurich (Switzerland)
- 3. University Hospital Zurich, Department of Visceral and Transplantation Surgery, Zurich (Switzerland)
- 4. University of Zurich, Department of Biostatistics, Zurich (Switzerland)
- 5. GE Healthcare, Buc Cedex (France)
Description
The purpose of this study was to compare respiratory-triggered balanced steady-state free precession (bSSFP) with breath-hold contrast-enhanced dynamic two-dimensional (2D) gradient-echo (GRE) and time-of-flight (TOF) magnetic resonance imaging (MRI) for portal and hepatic vein visualization and assessment of portal and hepatic venous variants. Sixty patients with liver disease underwent nonenhanced bSSFP and contrast-enhanced GRE, bSSFP, and TOF imaging. Contrast-to-noise ratios (CNRs) for portal and hepatic veins were measured. Two readers rated the quality of portal and hepatic vein visualization on a 5-point Likert scale. The diagnostic performance of each MRI series in the detection of portal and hepatic venous variants was assessed in 40/60 patients who also underwent contrast-enhanced multidetector-row computed tomography (MDCT). CNRs for portal and hepatic veins were highest on contrast-enhanced bSSFP images. Image quality of portal and hepatic veins was rated higher for nonenhanced bSSFP than for contrast-enhanced GRE (p<0.03) and TOF (p<0.003) and higher for contrast-enhanced than for nonenhanced bSSFP (p<0.003). Compared with MDCT, portal and hepatic venous variants were identified with an accuracy of 99% on bSSFP images, with an excellent interobserver agreement (κ=0.97). Compared with MDCT, presence of surgically important portal and hepatic venous anatomical variants can be predicted with high accuracy on bSSFP images. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-006-0305-3Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 17
- Journal Issue
- 1
- Journal Page Range
- p. 229-240
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 38044174
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BREATH; DIAGNOSIS; DIGESTIVE SYSTEM DISEASES; LIVER; TIME-OF-FLIGHT METHOD
- Descriptors DEC
- BODY; DIGESTIVE SYSTEM; DISEASES; GLANDS; ORGANS