Published June 26, 2013
| Version v1
Journal article
The effect of motion on IMRT – looking at interplay with 3D measurements
- 1. Duke University Medical Center, Durham, NC (United States)
- 2. Rider University, Lawerenceville, NJ (United States)
Description
Six base of skull IMRT treatment plans were delivered to 3D dosimeters within the RPC Head and Neck Phantom for QA verification. Isotropic 2mm 3D data was obtained using the DLOS-PRESAGE system and compared to an Eclipse (Varian) treatment plan. Normalized Dose Distribution pass rates were obtained for a number of criteria. High quality 3D dosimetry data was observed from the DLOS system, illustrated here through colormaps, isodose lines, profiles, and NDD 3D maps. Excellent agreement with the planned dose distributions was also observed with NDD analysis revealing > 90% NDD pass rates [3%, 2mm], noise < 0.5%. This paper focuses on a detailed exploration of the quality and use of 3D dosimetry data obtained with the DLOS-PRESAGE system.
Availability note (English)
Available from http://dx.doi.org/10.1088/1742-6596/444/1/012049Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Physics. Conference Series (Online)
- Journal Volume
- 444
- Journal Issue
- 1
- Journal Page Range
- [4 p.]
- ISSN
- 1742-6596
Conference
- Title
- 7. international conference on 3D radiation dosimetry
- Acronym
- IC3DDose
- Dates
- 4-8 Dec 2012
- Place
- Sydney (Australia)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44074769
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSEMETERS; DOSIMETRY; HEAD; MAPS; NECK; PHANTOMS; RADIATION DOSE DISTRIBUTIONS; SKULL; VERIFICATION
- Descriptors DEC
- BODY; MEASURING INSTRUMENTS; MOCKUP; ORGANS; SKELETON; STRUCTURAL MODELS