Injection timing system for PLS

  • 1. Pohang Inst. of Science and Technology (Korea, Republic of). Pohang Accelerator Lab.

Description

The ultimate goal of the PLS timing system is to successfully inject a electron bunch to a predesigned bucket in the Storage Ring. In the Linac, a pretrigger of 102.8 microseconds prior to the Gun trigger may be required to charge the pulsed devices properly and it should be precisely delayed to synchronize with beam pass at each accelerating column. To inject the electron bunch, which fully accelerated in the Linac, into a target bucket of SR, the injection kicker magnets must be energized to provide the appropriate magnetic field. For the sequential filling of the SR buckets, the appropriate timing delays throughout the entire timing system are programmably controlled by operator. (author)

Files

25044490.pdf

Files (115.2 kB)

Name Size Download all
md5:86bb4c1872438f624cd87fb6920e4ea0
115.2 kB Preview Download
Part of:
Proceedings of international conference on accelerators and large experimental physics control systems

Additional details

Publishing Information

Imprint Title
Proceedings of international conference on accelerators and large experimental physics control systems
Imprint Pagination
658 p.
Journal Page Range
p. 349-351.
Report number
KEK-PROC--92-15

Conference

Title
International conference on accelerators and large experimental physics control systems.
Dates
11-15 Nov 1991.
Place
Tsukuba, Ibaraki (Japan).

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
25044490
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM INJECTION; CONTROL SYSTEMS; KOREAN ORGANIZATIONS; LINEAR ACCELERATORS; PULSE CIRCUITS; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES; TIMING CIRCUITS; TRIGGER CIRCUITS
Descriptors DEC
ACCELERATORS; ELECTRONIC CIRCUITS; NATIONAL ORGANIZATIONS; RADIATION SOURCES

Optional Information