Lithium isotopic analysis by optical emission spectroscopy
Creators
- 1. Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Dept. de Quimica
- 2. Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Gerencia de Procesos Quimicos
Description
Optical emission spectroscopy has been used to discriminate isotopic composition differences in the range of 92.6% (natural isotopic mixture) to 99.7% of /sup 7/Li. A desmountable hollow-cathode lamp was employed as an emission source for the lines /sup 2/S/sub 1/2/ - /sup 2/P/sub 1/2,3/2/ (670.8 nm), the isotopic displacement (15 pm) being of the same magnitude as the fine structure. The lines were resolved with a 3.4 m Ebert-Fastie spectrograph employed in a high dispersion mode (second order of a 1180 grooves/mm grating; theoretical resolution power: 360.000;linear reciprocal dispersion:77 pm/mm). The emission characteristics of the lamp (current intensity and argon gas pressure) were previously studied with a low resolution monochromator with photoelectric detection. In the spectrograph, the resolved doublets were photographied with a 1 N emulsion; the line transmittances were measured with a recording microphotometer. A plot of the line exposure ratio vs. isotopic composition of [/sup 2/S/sub 1/2/ -/sup 2/P/sub 3/2/ (/sup 7/Li)] relative to ([/sup 2/S/sub 1/2/ - /sup 2/P/sub 1/2/ (/sup 7/Li)] + [/sup 2/S/sub 1/2/ -/sup 2/P/sub 3/2/ (/sup 6/Li)]) gave a linear analytical curve (correlation coefficient = 0.992 for N = 4) over the tested range. (M.E.L.)
Abstract (Spanish)
Para discriminar diferenciass de composiciones isotopicas en el intervalo de 92,6% a 99,7% de /sup 7/Li (mezcla isotopica natural) se utilizo una lampara desmontable de catodo hueco como fuente de emision de las lineas /sup 2/S/sub 1/2/ - /sup 2/P/sub 1/2,3/2/ (670,8 nm), cuyo desplazamiento isotopico (15 pm) es de la misma magnitud que la separacion correspondiente a la estructura fina; esta se resolvio mediante un espectrografo Ebert-Fastie de 3,4 m empleado en condiciones de alta dispersion (segundo orden de la red de 1180 lineas/mm; resolucion teorica: 360.000; dispersion lineal reciproca: 77 pm/mm). Las condiciones de emision de la lampara (intensidad de corriente y presion de gas argon) se estudiaron con un monocromador de baja resolucion y deteccion fotoelectrica. En el espectrografo, los dobletes resueltos se fotografiaron con emulsion 1 N; las transmitancias de las lineas se midieron con un microfotometro registrador. Los cocientes de los valores de las exposiciones relativas de las lineas [/sup 2/S/sub 1/2/ - /sup 2/P/sub /3/2/ (de /sup 7/Li)] con respecto a ([/sup 2/S/sub 1/2/ - /sup 2/P/sub 1/2/ (de /sup 7/Li)] + [/sup 2/S/sub 1/2/ -/sup 2/P/sub 3/2/ (de /sup 6/Li)]) permitieron obtener una curva analitica lineal (resolucion teorica = 0,992 para N = 4) en el intervalo de composiciones ensayado. (M.E.L.)Additional details
Additional titles
- Original title (Spanish)
- Analisis isotopico del litio por espectroscopia de emision optica
Publishing Information
- Journal Title
- Anal. Asoc. Quim. Argent.
- Journal Volume
- 70
- Journal Issue
- 2
- Series
- Anal. Asoc. Quim. Argent.
- Journal Page Range
- 231-235
- ISSN
- 0365-0375
INIS
- Country of Publication
- Argentina
- Country of Input or Organization
- Argentina
- INIS RN
- 14749002
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ABSORPTION SPECTROSCOPY; EMISSION SPECTROSCOPY; LITHIUM; QUANTITATIVE CHEMICAL ANALYSIS
- Descriptors DEC
- ALKALI METALS; CHEMICAL ANALYSIS; ELEMENTS; METALS; SPECTROSCOPY