Published January 2005 | Version v1
Journal article

Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4

  • 1. Health Physics Unit, Tarapur Atomic Power Station 3 and 4, Tarapur (India)

Description

Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was found that the finding of the study was utilized for the shielding augmentation. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection and Environment
Journal Volume
28
Journal Issue
1-4
Journal Page Range
p. 106-107
CODEN
RPREFM

Conference

Title
27. IARP national conference on occupational and environmental radiation protection
Acronym
IARPNC 2005
Dates
23-25 Nov 2005
Place
Mumbai (India)

Optional Information

Notes
3 refs., 1 fig., 1 tab.