The Delphi time projection chamber

Description

The DELPHI central tracking device, a Time Projection Chamber, is described. Its performances in terms of resolution and particle identification are reviewed. Details on operation procedure, as calibration and distortion studies, are given

Availability note (English)

MF available from INIS under the Report Number.

Files

24027465.pdf

Files (216.7 kB)

Name Size Download all
md5:88fd69c63d39b3ee66a117435ee86414
216.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
CEA-DAPNIA-SPP--92-08

Conference

Title
6. International Wire Chamber Conference.
Dates
17-21 Feb 1992.
Place
Vienna (Austria).

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
24027465
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALIBRATION; ENERGY RESOLUTION; LEP STORAGE RINGS; PARTICLE IDENTIFICATION; PERFORMANCE; RADIATION DETECTORS; TIME PROJECTION CHAMBERS
Descriptors DEC
DRIFT CHAMBERS; MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBER; PROPORTIONAL COUNTERS; RESOLUTION; STORAGE RINGS