Published August 2015 | Version v1
Journal article

Analysis and solution of unable tripping fault of refueling machine gripper

Creators

  • 1. CNNC Nuclear Power Operations Management Co., Ltd, Haiyan (China)

Description

Fuel assembly gripper driving circuit is a key part of the refueling machine. Its reliability has great significance for safety and stability of refueling operation. A number of tripping faults have occurred since the operation of the refueling machine No.1 and No.2 of Qinshan nuclear power plant II, and it has a certain impact on the refueling operation. With gripper driving circuit as the research object, considering the fault phenomenon and the maintenance experiences, the reasons of key components defect were analyzed in detail, the troubleshooting methods and solutions were summarized, and the measures to solve the problem was provided. (author)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
36
Journal Issue
4
Journal Page Range
p. 133-135
ISSN
0258-0926

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
49047447
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
DEFECTS; FUEL ASSEMBLIES; FUELS; MAINTENANCE; NUCLEAR POWER PLANTS; OPERATION; RELIABILITY; SAFETY; STABILITY
Descriptors DEC
NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Notes
1 tab., 2 refs.