Published 2004 | Version v1
Book

Analysis of a convection loop for GFR post-LOCA decay heat removal

  • 1. Nuclear Engineering Department, Massachusetts Institute of Technology, Cambridge (United States)

Description

A computer code (LOCA-COLA) has been developed at MIT for steady state analysis of convective heat transfer loops. In this work, it is used to investigate an external convection loop for decay heat removal of a post-LOCA gas-cooled fast reactor (GFR). The major finding is that natural circulation cooling of the GFR is feasible under certain circumstances. Both helium and CO2 cooled system components are found to operate in the mixed convection regime, the effects of which are noticeable as heat transfer enhancement or degradation. It is found that CO2 outdoes helium under identical natural circulation conditions. Decay heat removal is found to have a quadratic dependence on pressure in the laminar flow regime and linear dependence in the turbulent flow regime. Other parametric studies have been performed as well. In conclusion, convection cooling loops are a credible means for GFR decay heat removal and LOCA-COLA is an effective tool for steady state analysis of cooling loops. (authors)

Part of:
Proceedings of the 12. international conference on nuclear engineering

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers - ASME
Imprint Place
New York (United States)
ISBN
0-7918-4687-3
Imprint Title
Proceedings of the 12. international conference on nuclear engineering
Imprint Pagination
924 p.
Journal Page Range
p. 753-762

Conference

Title
12. international conference on nuclear engineering - ICONE 12
Dates
25-29 Apr 2004
Place
Arlington - Virginia (United States)

Optional Information

Notes
22 refs.