Published August 1983 | Version v1
Book

A decay heat removal system requiring no external energy

  • 1. CEA/IPSN/DAS, Fontenay-aux-Roses

Description

A new Decay Heat Removal System is described for PWRs with dry containment. This new system is intended to provide a high level of safety since it uses no external energy, but only the thermodynamic energy of the air-steam-liquid water mixture generated in the containment after failure of the primary circuit or of the secondary circuit. A schematic drawing of the system is presented. Thermodynamics of the system are evaluated and design considerations are discussed. The use of the system for protecting actual PWRs is addressed

Additional details

Publishing Information

Publisher
Stone and Webster Engineering Corporation.
Imprint Place
Boston, MA (USA)
Imprint Title
Light water reactor severe accident evaluation
Journal Page Range
p. 3.4-1-3.4-7.

Conference

Title
International meeting on light-water reactor severe accident evaluation.
Dates
28 Aug - 1 Sep 1983.
Place
Cambridge, MA (USA).