Published October 1985
| Version v1
Journal article
Cavity-coupling investigation for the phermex 50 MHz RF accelerator
Description
The PHERMEX accelerator is a three-cavity rf linac that operates at 50 MHz. Each cavity has a radius of 2.3 m and a length of 2.6 m. The accelerator produces an electron beam with a peak current of 500 A and energy of 30 MeV. RF power is supplied by multiple 2.5-MW tetrodes feeding coaxial lines with loops in the cavity wall. To increase the fields, multiple tetrodes and coupling loops must be used in each cavity; the problems associated with multiple-loop coupling are investigated
Additional details
Publishing Information
- Journal Title
- IEEE Trans. Nucl. Sci.
- Journal Volume
- NS-32
- Journal Issue
- 5
- Series
- IEEE Trans. Nucl. Sci.
- Journal Page Range
- 2852-2853
- ISSN
- 0018-9499
- CODEN
- IETNA
Conference
- Title
- Particle accelerator conference.
- Dates
- 13-16 May 1985.
- Place
- Vancouver (Canada).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17051242
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AMP BEAM CURRENTS; CAVITY RESONATORS; COUPLING; ELECTRON BEAMS; LINEAR ACCELERATORS; MEV RANGE 10-100; MHZ RANGE 01-100; RF SYSTEMS
- Descriptors DEC
- ACCELERATORS; BEAM CURRENTS; BEAMS; CURRENTS; ELECTRONIC EQUIPMENT; ENERGY RANGE; EQUIPMENT; FREQUENCY RANGE; LEPTON BEAMS; MEV RANGE; MHZ RANGE; PARTICLE BEAMS; RESONATORS
Optional Information
- Secondary number(s)
- CONF-850504--.