Published October 1985 | Version v1
Journal article

Cavity-coupling investigation for the phermex 50 MHz RF accelerator

  • 1. Los Alamos National Laboratory, Los Alamos, NM

Description

The PHERMEX accelerator is a three-cavity rf linac that operates at 50 MHz. Each cavity has a radius of 2.3 m and a length of 2.6 m. The accelerator produces an electron beam with a peak current of 500 A and energy of 30 MeV. RF power is supplied by multiple 2.5-MW tetrodes feeding coaxial lines with loops in the cavity wall. To increase the fields, multiple tetrodes and coupling loops must be used in each cavity; the problems associated with multiple-loop coupling are investigated

Additional details

Publishing Information

Journal Title
IEEE Trans. Nucl. Sci.
Journal Volume
NS-32
Journal Issue
5
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
2852-2853
ISSN
0018-9499
CODEN
IETNA

Conference

Title
Particle accelerator conference.
Dates
13-16 May 1985.
Place
Vancouver (Canada).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17051242
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AMP BEAM CURRENTS; CAVITY RESONATORS; COUPLING; ELECTRON BEAMS; LINEAR ACCELERATORS; MEV RANGE 10-100; MHZ RANGE 01-100; RF SYSTEMS
Descriptors DEC
ACCELERATORS; BEAM CURRENTS; BEAMS; CURRENTS; ELECTRONIC EQUIPMENT; ENERGY RANGE; EQUIPMENT; FREQUENCY RANGE; LEPTON BEAMS; MEV RANGE; MHZ RANGE; PARTICLE BEAMS; RESONATORS

Optional Information

Secondary number(s)
CONF-850504--.