Published April 1987
| Version v1
Report
Restricted
High-Temperature Reactor Module Power Plant: Safety Analysis Report. Conduct of Operations. Chapter 5.2
Creators
Description
Chapter 5.2 of the High-Temperature Reactor Module Power Plant: Safety Analysis Report. The HTR Module NPP design is tailored to the requirements imposed by the electric grid and the process steam System. The central consideration is the demand for high availability of process steam supply and power generation. For this reason the power plant essentially consists of two identical 50%-duty power plants which are suitably interconnected. This makes it possible to continue Operation of one module during overhauls in the other or on failure of plant items without interruption of power Operation, possibly at reduced power.
Files
Additional details
Publishing Information
- Imprint Pagination
- 20 p.
- Report number
- INIS-DE--22M0297
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 53061873
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S42: ENGINEERING;
- Descriptors DEI
- DESIGN; FEDERAL REPUBLIC OF GERMANY; FORSCHUNGSZENTRUM JUELICH; HTGR TYPE REACTORS; NUCLEAR POWER PLANTS; OPERATION; POWER GENERATION; SAFETY ANALYSIS; STEAM; STEAM SYSTEMS; TEMPERATURE RANGE 0400-1000 K
- Descriptors DEC
- DEVELOPED COUNTRIES; ENERGY SYSTEMS; EUROPE; GAS COOLED REACTORS; GERMAN FR ORGANIZATIONS; GRAPHITE MODERATED REACTORS; NATIONAL ORGANIZATIONS; NUCLEAR FACILITIES; POWER PLANTS; REACTORS; TEMPERATURE RANGE; THERMAL POWER PLANTS; WESTERN EUROPE
Optional Information
- Notes
- Document from Juelich Preservation Project; Also available in German; Figs.