Published April 1987 | Version v1
Report Restricted

High-Temperature Reactor Module Power Plant: Safety Analysis Report. Conduct of Operations. Chapter 5.2

Description

Chapter 5.2 of the High-Temperature Reactor Module Power Plant: Safety Analysis Report. The HTR Module NPP design is tailored to the requirements imposed by the electric grid and the process steam System. The central consideration is the demand for high availability of process steam supply and power generation. For this reason the power plant essentially consists of two identical 50%-duty power plants which are suitably interconnected. This makes it possible to continue Operation of one module during overhauls in the other or on failure of plant items without interruption of power Operation, possibly at reduced power.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
20 p.
Report number
INIS-DE--22M0297

Optional Information

Notes
Document from Juelich Preservation Project; Also available in German; Figs.