External quality control of determinations of tumour-associated antigens
- 1. Bonn Univ. (Germany, F.R.). Inst. fuer Klinische Biochemie
- 2. Inst. fuer Medizinische Statistik, Dokumentation und Datenverarbeitung, Universitaet Bonn (Germany, F.R.)
Description
Within the frame of the quality-control scheme of the German Society for Clinical Chemistry, an external quality-control survey for tumour-associated antigens was performed in November 1981. One hundred and twenty-one laboratories received two samples each of lyophilized human serum which was spiked with the analytes carcino-embryonic antigen (CEA), alpha-fetoprotein (AFP), and human chorionic gonadotropin (HCG). When giving the analytical values for HCG the participants could differentiate, depending on the antibodies used, between HCG, #betta#-HCG and HCG+#betta#-HCG. Seventy-five laboratories of the Federal Republic of Germany and 19 from other European countries sent their results for evaluation. The considerable interlaboratory imprecision of the analytical results cannot only be reduced to mistakes of the analysts. To a greater extent the varying analytical prerequisites of the different kits also had an effect. Furthermore, it must be assumed that many analysts have insufficient information about the reagents used. (author)
Additional details
Publishing Information
- Publisher
- IAEA.
- Imprint Place
- Vienna
- ISBN
- 92-0-010482-7
- Imprint Title
- Radioimmunoassay and related procedures in medicine 1982
- Imprint Pagination
- 825 p.
- Series
- Proceedings series.
- Journal Page Range
- p. 645-652.
Conference
- Title
- International symposium on radioimmunoassay and related procedures in medicine.
- Dates
- 21-25 Jun 1982.
- Place
- Vienna (Austria).
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 14771859
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; ANTIBODIES; ANTIGENS; BLOOD SERUM; CARCINOMAS; HCG; INTERLABORATORY COMPARISONS; QUALITY CONTROL; QUANTITATIVE CHEMICAL ANALYSIS; QUANTITY RATIO; RADIOENZYMATIC ASSAY; RADIOIMMUNOASSAY
- Descriptors DEC
- BIOLOGICAL MATERIALS; BLOOD; BLOOD PLASMA; BODY FLUIDS; CHEMICAL ANALYSIS; CONTROL; DISEASES; GONADOTROPINS; HORMONES; ISOTOPE APPLICATIONS; MATERIALS; NEOPLASMS; PEPTIDE HORMONES; PITUITARY HORMONES; TRACER TECHNIQUES
Optional Information
- Secondary number(s)
- IAEA-SM--259/48.