Within the frame of the quality-control scheme of the German Society for Clinical Chemistry, an external quality-control survey for tumour-associated antigens was performed in November 1981. One hundred and twenty-one laboratories received two samples each of lyophilized human serum which was spiked with the analytes carcino-embryonic antigen (CEA), alpha-fetoprotein (AFP), and human chorionic gonadotropin (HCG). When giving the analytical values for HCG the participants could differentiate, depending on the antibodies used, between HCG, #betta#-HCG and HCG+#betta#-HCG. Seventy-five laboratories of the Federal Republic of Germany and 19 from other European countries sent their results for evaluation. The considerable interlaboratory imprecision of the analytical results cannot only be reduced to mistakes of the analysts. To a greater extent the varying analytical prerequisites of the different kits also had an effect. Furthermore, it must be assumed that many analysts have insufficient information about the reagents used. (author)

Part of:
Radioimmunoassay and related procedures in medicine 1982

Additional details

Publishing Information

Publisher
IAEA.
Imprint Place
Vienna
ISBN
92-0-010482-7
Imprint Title
Radioimmunoassay and related procedures in medicine 1982
Imprint Pagination
825 p.
Series
Proceedings series.
Journal Page Range
p. 645-652.

Conference

Title
International symposium on radioimmunoassay and related procedures in medicine.
Dates
21-25 Jun 1982.
Place
Vienna (Austria).

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
14771859
Subject category
S60: APPLIED LIFE SCIENCES;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; ANTIBODIES; ANTIGENS; BLOOD SERUM; CARCINOMAS; HCG; INTERLABORATORY COMPARISONS; QUALITY CONTROL; QUANTITATIVE CHEMICAL ANALYSIS; QUANTITY RATIO; RADIOENZYMATIC ASSAY; RADIOIMMUNOASSAY
Descriptors DEC
BIOLOGICAL MATERIALS; BLOOD; BLOOD PLASMA; BODY FLUIDS; CHEMICAL ANALYSIS; CONTROL; DISEASES; GONADOTROPINS; HORMONES; ISOTOPE APPLICATIONS; MATERIALS; NEOPLASMS; PEPTIDE HORMONES; PITUITARY HORMONES; TRACER TECHNIQUES

Optional Information

Secondary number(s)
IAEA-SM--259/48.