Analysis of a dc commutator machine for exchange of energy with a superconducting coil

Description

A 500-kW dc commutator machine, C, is analyzed for use in an LC circuit with a ringing period of approximately 4 s with a superconducting coil, L. Electrical measurements and the important design equations and characteristics are listed. Attention is paid to the calculation of the commutating voltage, which is an important design feature because it sets a limit to the current allowable in the LC circuit, amounting to 6 times rated machine current. The equations for the energy loss components of the generator are given and fitted to experimental coast-down data. With a fitting accuracy of 1.2%, the loss coefficients for the bearing loss, brush loss, windage loss, and tooth eddy current loss in the remanent stator field are thus determined

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
18 p.
Report number
LA--7447-MS

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
10439310
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ELECTRIC COILS; ELECTRIC GENERATORS; ENERGY LOSSES; ENERGY STORAGE; ENERGY TRANSFER; PERFORMANCE; SPECIFICATIONS; SUPERCONDUCTING DEVICES
Descriptors DEC
ELECTRICAL EQUIPMENT; STORAGE