Published October 1, 1995 | Version v1
Journal article

Performance of a beam telescope using double sided silicon microstrip detectors

  • 1. Bonn Univ. (Germany). Physikalisches Inst.
  • 2. European Organization for Nuclear Research, Geneva (Switzerland)

Description

A beam telescope consisting of four double sided, DC coupled microstrip detectors with VLSI readout electronics has been built and tested in a 70 GeV μ- beam at CERN. A signal-to-noise ratio of 53:1 and a spatial resolution of 2.7μm (junction side) and 4.8μm (ohmic side) have been observed on the best detectors. A telescope performance for a particle track of σxy 2-3μm and σslope = 2-3μrad on the front face of a test object was achieved. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
364
Journal Issue
2
Journal Page Range
p. 224-230.
ISSN
0168-9002
CODEN
NIMAER