Published October 2016
| Version v1
Journal article
Simulation for compensation of superconducting cavity in C-ADS injector
Creators
- 1. Institute of High Energy Physics CAS, Beijing (China)
- 2. University of the Chinese Academy of Sciences, Beijing (China)
Description
For the proton accelerators such as the China Accelerator Driven subcritical System (C-ADS), it is essential and difficult to achieve extremely high performance reliability requirement. Aiming at the failure problem of superconducting cavity in Injector-I in C-ADS, this paper gives simulation results based on Experimental Physics and Industrial Control System (EPICS) and PLC with embedded Linux system. The simulation completes the development of embedded system and quick seeking of data. The results not only verify the feasibility of such method, but also establish the foundation for further experiment. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 36
- Journal Issue
- 10
- Journal Page Range
- p. 1016-1019
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 53032608
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- ACCELERATOR-DRIVEN SUBCRITICAL SYSTEMS; BEAM INJECTION; CHINA; COMPUTERIZED SIMULATION; CONTROL SYSTEMS; FAILURES; PERFORMANCE; PROTON BEAMS; RELIABILITY; SUPERCONDUCTING CAVITY RESONATORS
- Descriptors DEC
- ASIA; BEAMS; CAVITY RESONATORS; ELECTRONIC EQUIPMENT; EQUIPMENT; EXPERIMENTAL REACTORS; NUCLEON BEAMS; PARTICLE BEAMS; REACTORS; RESEARCH AND TEST REACTORS; RESONATORS; SIMULATION; SUBCRITICAL ASSEMBLIES; SUPERCONDUCTING DEVICES
Optional Information
- Notes
- 8 figs., 8 refs.