Published October 2016 | Version v1
Journal article

Simulation for compensation of superconducting cavity in C-ADS injector

  • 1. Institute of High Energy Physics CAS, Beijing (China)
  • 2. University of the Chinese Academy of Sciences, Beijing (China)

Description

For the proton accelerators such as the China Accelerator Driven subcritical System (C-ADS), it is essential and difficult to achieve extremely high performance reliability requirement. Aiming at the failure problem of superconducting cavity in Injector-I in C-ADS, this paper gives simulation results based on Experimental Physics and Industrial Control System (EPICS) and PLC with embedded Linux system. The simulation completes the development of embedded system and quick seeking of data. The results not only verify the feasibility of such method, but also establish the foundation for further experiment. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
36
Journal Issue
10
Journal Page Range
p. 1016-1019
ISSN
0258-0934

Optional Information

Notes
8 figs., 8 refs.