Published October 2015 | Version v1
Journal article

New development of EPICS based data acquisition system for H-Alpha diagnostic

Description

Highlights: • The H-Alpha DAQ system was modified to measure the low current signal from the PMT. • We developed a new H-Alpha data acquisition system with a CPCI based digitizer. • We developed a signal conditioning box for converting the current to voltage. • The new signal condition box (SCB) has three input range level (400 nA, 1 μA and 2 μA). • It was successfully performed and stably operates more than the previous DAQ system. - Abstract: The H-Alpha diagnostic system has been developed to measure the line integrated intensity in the direction of toroidal and poloidal. The data acquisition (DAQ) system for H-Alpha diagnostics of the Korea Superconducting Tokamak Advanced Research (KSTAR) at the beginning of the first plasma in 2008 was developed with VME form factor digitizer in the Linux OS platform. The VME digitizer module of H-Alpha data acquisition system was modified to measure the low current signal from the photo-multiplier tubes (PMT). The input maximum current values of modified digitizer module are 400 nA and low current data is expressed as the value of the voltage between −10 V and +10 V. At first time, there was no problem to measure H-Alpha signal, but it could not measure the H-Alpha data signal as the KSTAR Plasma density increased. It exceeds digitizer input range, which means the H-Alpha signal is over 400 nA, so we should manually change the resistor on the digitizer board to measure the 400 nA over current. This is not easy to do and showed instability in the long time operation with high sampling data acquisition. In order to overcome these weak points, a new H-Alpha data acquisition system has been developed with a compact PCI (cPCI) based digitizer and a signal conditioning box for converting the current to voltage in the Linux OS platform. The new data acquisition system was developed based on Experimental Physics and Industrial Control System (EPICS) framework like other KSTAR diagnostics with standard framework (SFW). The main advantages of the new H-Alpha data acquisition system are the capabilities of calculating line integrated intensity during the plasma shot and displaying it in run-time. During the plasma shot, the new data acquisition system performs segment archiving data in MDSplus DB of KSTAR central storage. This paper describes the overview of new H-Alpha data acquisition system with signal condition box, the results of its implementation.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.fusengdes.2015.06.112

Additional details

Identifiers

DOI
10.1016/j.fusengdes.2015.06.112;
PII
S0920-3796(15)30139-3;

Publishing Information

Journal Title
Fusion Engineering and Design
Journal Volume
96-97
Journal Page Range
p. 826-829
ISSN
0920-3796
CODEN
FEDEEE

Conference

Title
28. symposium on fusion technology
Acronym
SOFT-28
Dates
29 Sep - 3 Oct 2014
Place
San Sebastian (Spain)

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.