Published March 30, 1999 | Version v1
Report

Current practice of LPSA in Hungary

  • 1. VEIKI Institute for Electric Power Research Co., H-1016 Budapest, Gellerthegy u. 17. (Hungary)
  • 2. Paks Nuclear Power Plant Co., H-7030 Paks (Hungary)

Description

This paper summarises and gives an overview of the living PSA (LPSA) procedure used in Hungary to update the PSA model and its documentation of the Paks NPP units. In recent years unit-specific PSAs have been developed for the units of VVER-440/213 type NPP of Paks to assess the general level of their safety, to identify plant weaknesses, and to outline necessary safety upgrading measures. The PSAs performed have been limited to level-1 and to internal initiating events. Since completion of the original unit-specific PSAs several safety related modifications of the technological systems have been made, as well as operational changes described in related procedures have been introduced. These changes make it necessary to update the risk model of the plant on given conditions to reflect their impact on the plant safety. Therefore the use of an LPSA has become necessary. (authors)

Part of:
Proceedings of the workshop on reliability data collection

Additional details

Publishing Information

Imprint Title
Proceedings of the workshop on reliability data collection
Imprint Pagination
260 p.
Journal Page Range
p. 63-69
Report number
NEA-CSNI-R--1998-10

Conference

Title
Workshop on reliability data collection
Dates
21-23 Apr 1998
Place
Budapest (Hungary)

Optional Information