Published 1981
| Version v1
Report
Open
Effects of source-fissile material distributions on the accuracy of time correlated counting
Description
Time correlated counting has been proposed as a possible criticality monitor at the Transuranic Waste Treatment Facility (TWTF). This paper investigates possible errors which might arise in estimates of k/sub eff/ due to the assumption implicit in time correlated counting, that neutron multiplication is constant from generation to generation. It appears that the assumption of uniform multiplication of neutrons between generations will not generally produce large errors in time correlated counting. However, a point source at the edge of a system could produce large errors
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.Files
12639249.pdf
Files
(123.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:4cec1d7d35df3829e76628cb9b9c801c
|
123.7 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- CONF-810606--81
Conference
- Title
- American Nuclear Society's annual meeting.
- Dates
- 7 - 12 Jun 1981.
- Place
- Miami Beach, FL, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12639249
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CORRELATIONS; COUNTING TECHNIQUES; CRITICALITY; INCINERATORS; MONITORING; PYROLYSIS; RADIOACTIVE WASTE FACILITIES; RADIOACTIVE WASTE PROCESSING; SLAGS
- Descriptors DEC
- CHEMICAL REACTIONS; DECOMPOSITION; MANAGEMENT; NUCLEAR FACILITIES; WASTE MANAGEMENT; WASTE PROCESSING