Published April 2002 | Version v1
Journal article

The design of radiological equivalent artificial bone materials

  • 1. Sichuan Univ., Chengdu (China). Dept. of Chemistry

Description

A relative mathematic model related to energy of rays and mass attenuation coefficient has been deduced according to the principles of the interactions between X-ray or γ-ray, substances, the characteristics of component distribution of bone tissues and radiation attenuation. The model has provided a theoretical basis of designs of radiological equivalent bone materials and a practical calculation method for selecting artificial bone materials and determining their formulations

Additional details

Publishing Information

Journal Title
Journal of Sichuan University. Natural Science Edition
Journal Volume
39
Journal Issue
2
Journal Page Range
p. 294-298
ISSN
0490-6756
CODEN
SCTHAO