Published April 2002
| Version v1
Journal article
The design of radiological equivalent artificial bone materials
Description
A relative mathematic model related to energy of rays and mass attenuation coefficient has been deduced according to the principles of the interactions between X-ray or γ-ray, substances, the characteristics of component distribution of bone tissues and radiation attenuation. The model has provided a theoretical basis of designs of radiological equivalent bone materials and a practical calculation method for selecting artificial bone materials and determining their formulations
Additional details
Publishing Information
- Journal Title
- Journal of Sichuan University. Natural Science Edition
- Journal Volume
- 39
- Journal Issue
- 2
- Journal Page Range
- p. 294-298
- ISSN
- 0490-6756
- CODEN
- SCTHAO
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 35033167
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ARTIFICIAL ORGANS; BONE TISSUES; DESIGN; DOSE EQUIVALENTS; GAMMA RADIATION; MATERIALS; MATHEMATICAL MODELS; RADIATION ATTENUATION TESTING; X RADIATION
- Descriptors DEC
- ANIMAL TISSUES; BODY; CONNECTIVE TISSUE; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; RADIATIONS; TESTING