Published December 2003 | Version v1
Book

The response and the intrinsic time resolution of the large BaF2 array at VECC

  • 1. Variable Energy Cyclotron Centre, Kolkata (India)
  • 2. UGC Research Fellow, Burdwan Univ., Burdwan (India)

Description

The large BaF2 array (50 elements) at VECC has been completed and is ready for operation. Here, the resolution and linearity of the individual detectors using the 137Cs, 22Na, 60Co, 241Am-9Be radioactive sources have been reported. The intrinsic time resolution of a single BaF2 detector, measured with respect to another similar module using a 60Co standard gamma ray source is also reported

Part of:
DAE-BRNS symposium on nuclear physics: contributed papers. V. 46B

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
DAE-BRNS symposium on nuclear physics: contributed papers. V. 46B
Imprint Pagination
642 p.
Journal Page Range
p. 454-455

Conference

Title
46. DAE-BRNS symposium on nuclear physics
Dates
8-12 Dec 2003
Place
Mumbai (India)

Optional Information

Notes
3 figs.