Published August 1984 | Version v1
Report Open

Method for high absorbed dose measurement and standardization

  • 1. Office of Atomic Energy for Peace, Bangkok (Thailand)
  • 2. Boris Kidric Institute of Nuclear Sciene, Vinca (Yugoslavia)

Description

To establish the method for high absorbed dose measurements and standardization is important in the dose assurance of the product irradiation. The experiments using OAEP's cobalt-60 source including the homogeneity testing and the dose rate determination were employed by Fricke dosimeter. The cerium sulfate solutions were calibrated against the Fricke's dose rate, and the achieved G-value was within the possible range. The opti-chromic dosimeters were used as the cross-check of the locally calibrating system and the standard laboratories; the National Bureau of Standards (NBS), U.S.A. and the Boris Kidric Institute of Nuclear Science, Vinca, the results were within acceptable range

Availability note (English)

MF available from INIS under the Report Number.

Files

25050111.pdf

Files (609.7 kB)

Name Size Download all
md5:55a7143222528986f0c52a8771c8a8f2
609.7 kB Preview Download

Additional details

Publishing Information

ISBN
974-7399-16-4
Imprint Pagination
27 p.
Report number
OAEP--1-112