Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation
Creators
- 1. Ottawa Carleton Institute of Physics, Carleton University Campus, Ottawa K1S 5B6 (Canada)
Description
This article describes four methods of calculating the replacement correction factor, Prepl (or the product pcavpdis in the IAEA's notation), for a plane-parallel chamber in both electron and photon beams, and for a Farmer chamber in photon beams, by using the EGSnrc Monte Carlo code. The accuracy of underlying assumptions and relative merits of each technique are assessed. With careful selection of parameters it appears that all four methods give reasonable answers although the direct methods are more intellectually satisfying and more accurate in some cases. The direct methods are shown to have an accuracy of 0.1% when appropriate calculation parameters are selected. The depth dependence of Prepl for the NACP02 plane-parallel chamber has been calculated in both 6 and 18 MeV electron beams. At the reference depth (0.6R50-0.1 cm) Prepl is 0.9964 for the 6 MeV beam and 1.0005 for the 18 MeV beam for this well-guarded chamber; at the depth of maximum dose for the 18 MeV beam, Prepl is 1.0010. Prepl is also calculated for the NACP02 chamber and a Farmer chamber (diameter 6 mm) at a depth of 5 cm in a 60Co photon beam, giving values of 1.0063 and 0.9964, respectively. For the Farmer chamber, Prepl is about half a percent higher than the value (0.992) recommended by the AAPM dosimetry protocol. It is found that the dosimetry protocols may have adopted an incorrect value of Prepl for cylindrical chambers in photon beams. The nonunity values of Prepl for plane-parallel chambers in lower energy electron beams imply a variety of values used in dosimetry protocols must be reassessed
Additional details
Identifiers
- DOI
- 10.1118/1.2898139;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 35
- Journal Issue
- 5
- Journal Page Range
- p. 1747-1755
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40003202
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; COBALT 60; COMPUTERIZED SIMULATION; CORRECTIONS; DOSIMETRY; ELECTRON BEAMS; IONIZATION CHAMBERS; MONTE CARLO METHOD; PHOTON BEAMS
- Descriptors DEC
- BEAMS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CALCULATION METHODS; COBALT ISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LEPTON BEAMS; MEASURING INSTRUMENTS; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; PARTICLE BEAMS; RADIATION DETECTORS; RADIOISOTOPES; SIMULATION; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- (c) 2008 American Association of Physicists in Medicine