Full text: Backscatter from the robotic arm mechanism of an a-Si EPID in IMRT images was examined. Images corrected with a conventional flood field (FF) containing a backscatter component (BSC) from the robotic ann were compared with a BSC-free FF. A Yarian 21 EX linac (6 MV, 18 MV) was used. All images were acquired with two aS500 EPIDs, one R-arm and one E-arm. The BSC of an EPID image is the ratio of an image acquired with the EPID attached to the arm then detaching the arm from the EPID and acquiring the same image. A range of square field sizes from 2.5 x 2.5 cm to 27.5 x 27.5 cm were acquired and the BSC analyzed. The BSC of the FFs were also measured. A series of IMRT fields were acquired. Each field was corrected with a conventional FF and compared with a BSC-free FF. Figure I shows the magnitude of the BSC from each arm in the inplane for a 6x beam. Square fields above 16 x l6 cm (R-arm) and lO x 10 cm (E-arm) benefited from a conventional FF as it tended to cancel out the BSC in the acquired square field. The opposite was observed for smaller field sizes. A gamma analysis of the IMRT fields showed a FF correction containing a BSC reduces the effect of the arm in the final image. IMRT EPID images using conventional FFs have been shown to be less affected by backscatter from the robotic arm compared to BSC-free flood fields. (author)
Additional details
Publishing Information
- Publisher
- Australasian College of Physical Scientists and Engineers in Medicine
- Imprint Place
- Melbourne (Australia)
- Imprint Title
- Program EPSM-ABEC 2010 Conference
- Imprint Pagination
- 62 p.
- Journal Page Range
- p. 146
Conference
- Title
- Conference abstract
- Dates
- 5-9 Dec 2010
- Place
- Melbourne (Australia)
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- Australia
- INIS RN
- 43108923
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BACKSCATTERING; DIAGNOSTIC TECHNIQUES; GAMMA SOURCES; IMAGE PROCESSING; IMAGES; NMR IMAGING; NUCLEAR MAGNETIC RESONANCE; RADIATION SOURCES; SCATTERING
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; MAGNETIC RESONANCE; PROCESSING; RADIATION SOURCES; RESONANCE; SCATTERING