Validity of gradient-echo three-dimensional delayed gadolinium-enhanced magnetic resonance imaging of hip joint cartilage: A histologically controlled study
Creators
- 1. Univ Dusseldorf, Medical Faculty, Department of Orthopaedic Surgery, Moorenstraße 5, D-40225 Dusseldorf (Germany)
- 2. Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstraße 5, D-40225 Dusseldorf (Germany)
- 3. Univ Essen, Medical Faculty, Department of Orthopaedic Surgery, D-45147 Essen (Germany)
- 4. LVR Clinic for Orthopedic Surgery, D-41749 Viersen (Germany)
Description
Objective: To validate gradient-echo three-dimensional (3D) delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) by means of histological analyses in the assessment of hip joint cartilage. Materials and methods: Twenty-one femoral head specimens collected from 21 patients (7 males, 14 females, mean age: 60.9 ± 9.6 years; range: 37.6–77.3 years), who underwent total hip replacement for symptomatic hip joint osteoarthritis, underwent MRI and histological assessment. A region of 2 cm2 at the weight-bearing area was marked with four pins to enable multi-planar MRI reformatting to be matched with histological sections. MRI was performed at 3 T with a 3D double-echo steady-state (DESS) sequence for morphological cartilage assessment and 3D Volumetric Interpolated Breathhold Examination (VIBE) for T1Gd mapping. Histological sections were evaluated according to the Mankin score system. Total Mankin score, grade of toluidine staining (sensitive for glycosaminoglycan content) and a modified Mankin score classification system with four sub-groups of cartilage damage were correlated with MRI data. Results: Spearman's rho correlation analyses revealed a statistically significant correlation between T1Gd mapping and histological analyses in all categories including total Mankin score (r = −0.658, p-value ≤ 0.001), toluidine staining (r = −0.802, p-value < 0.001) and modified Mankin score (r = −0.716, p-value < 0.001). The correlation between morphological MRI and histological cartilage assessment was statistically significant but inferior to the biochemical cartilage MRI (r-values ranging from −0.411 to 0.525, p-values < 0.001). Conclusions: Gradient-echo dGEMRIC is reliable while offering the unique features of high image resolution and 3D biochemically sensitive MRI for the assessment of early cartilage degeneration
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2012.09.024Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2012.09.024;
- PII
- S0720-048X(12)00479-2;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 82
- Journal Issue
- 2
- Journal Page Range
- p. e81-e86
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Cuba
- INIS RN
- 46001257
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BEARINGS; CARTILAGE; CHARGES; CLASSIFICATION; CORRELATIONS; DAMAGE; DATA; GADOLINIUM; HEAD; IMAGES; JOINTS; MAPPING; NMR IMAGING; STAINS; STEADY-STATE CONDITIONS; THREE-DIMENSIONAL CALCULATIONS
- Descriptors DEC
- ANIMAL TISSUES; BODY; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; ELEMENTS; INFORMATION; METALS; RARE EARTHS
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.