Recirculation pump shaft cracking experience at Chin-Shan station

Creators

  • 1. Taiwan Nuclear Power Co., Taipei (Taiwan)

Description

This paper reviews the experience of the Chin-Shan Nuclear Power Station with recirculation pump shaft cracking experience. The topics of the paper include a description of the Chin-Shan boiling water reactor plant, a summary of the disassembly and inspection of the recirculation pump, a description of the provisions for pump inspection, the pump vibration monitoring system, and the location of accelerometers, proximity probes, keyphasor and velocity transducers