Published June 2018
| Version v1
Journal article
Monte Carlo studies and response assessment of a new Rotational Modulation Collimator (RMC) design
Creators
- 1. Sejong University, Seoul (Korea, Republic of). Department of Nuclear Engineering
Description
A Rotational Modulation Collimator (RMC) is a simple imaging technique with applications in homeland security for detecting nuclear materials and orphan radiation sources. These compose a threat for national security and it is therefore of utmost importance to develop fast and accurate systems to locate these threats. Here we propose a new RMC design, with increased field of view (FOV), where the body of the system includes slits. Monte Carlo simulations were performed to assess the response of the new design. Image reconstruction was performed using the Maximum Likelihood Expectation Maximization (MLEM) algorithm. The proposed design results in a RMC with an extended FOV of 60°. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Radioanalytical and Nuclear Chemistry
- Journal Volume
- 316
- Journal Issue
- 3
- Journal Page Range
- p. 1119-1128
- ISSN
- 0236-5731
- CODEN
- JRNCDM
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 49067494
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- COLLIMATORS; IMAGE PROCESSING; MAXIMUM-LIKELIHOOD FIT; MEASURING INSTRUMENTS; MONTE CARLO METHOD; RADIATION DETECTION
- Descriptors DEC
- CALCULATION METHODS; DETECTION; MATHEMATICAL SOLUTIONS; NUMERICAL SOLUTION; PROCESSING
Optional Information
- Notes
- 16 refs.