A novel method for increasing the sensitivity of NIPAM polymer gel dosimeter
- 1. Medical Radiation Department, Islamic Azad University, Science and Research Branch, Tehran (Iran, Islamic Republic of)
- 2. Physics Department, Imam Khomeini International University, P.O. Box 34149-16818, Qazvin (Iran, Islamic Republic of)
- 3. Department of Medical Physics and Radiology, Kashan University of Medical Sciences, Kashan (Iran, Islamic Republic of)
Description
Highlights: • Sensitivity of the NIPAM gel dosimeter was improved by adding urea. • The optimal amount of urea was determined 3%. • New formulation was named U-NIPAM. • Radiological properties of the U-NIPAM are equivalent to those of water and soft tissue. • Optimized U-NIPAM gel shows a sensitivity increase of about 37%. - Abstract: NIPAM polymer gel dosimeter has low toxicity and its response does not particularly depend on dose rate and beam energy. However, a chief drawback of the NPAM gel dosimeter is its relatively low sensitivity. In the current study, the sensitivity of the NIPAM gel dosimeter was improved by adding urea which this new formula gel dosimeter was called U-NIPAM (Urea and NIPAM) and optimal amount of urea for this new formula was evaluated. For this purpose, various concentrations of the urea (1%, 2%, 3% and 4% (w/w)) were tested. The samples were irradiated using 1.25 MeV and 6 MV photon energies and imaged by a 1.5 T MRI scanner. Then, the MRI response (R2) and the sensitivity of the conventional NIPAM and U-NIPAM gel dosimeters with different percentages of urea were analyzed at a 0–6 Gy dose range, different post irradiation time, and temperature during scanning. The radiological properties of U-NIPAM polymer gel dosimeter reveal that this substance can be considered as a water/soft tissue equivalent material. With analyzing the findings, it was found that the optimal amount of urea is 3%, because after this concentration, the R2-dose sensitivity of U-NIPAM gel dosimeter does not significantly changed (P >0.05). Furthermore, the results showed that using 3% urea in conventional NIPAM gel formulation leads to a sensitivity increase of around 37% (0.242 vs. 0.177 s−1 Gy−1). In addition, other results for optimized U-NIPAM gel dosimeter include: a) an excellent linear R2-dose response in 0–6 Gy dose range, and b) stability in the R2 value and the sensitivity for 18–21 °C temperatures.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radphyschem.2018.09.006Additional details
Identifiers
- DOI
- 10.1016/j.radphyschem.2018.09.006;
- PII
- S0969806X18303864;
Publishing Information
- Journal Title
- Radiation Physics and Chemistry (1993)
- Journal Volume
- 153
- Journal Page Range
- p. 35-43
- ISSN
- 0969-806X
- CODEN
- RPCHDM
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 51001983
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S38: RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR CHEMISTRY;
- Descriptors DEI
- DOSE RATES; NMR IMAGING; POLYMER GEL DOSEMETERS; POLYMER GEL DOSIMETRY; SENSITIVITY; TISSUE-EQUIVALENT MATERIALS; UREA
- Descriptors DEC
- AMIDES; CARBONIC ACID DERIVATIVES; CHEMICAL DOSEMETERS; DIAGNOSTIC TECHNIQUES; DOSEMETERS; DOSIMETRY; MATERIALS; MEASURING INSTRUMENTS; ORGANIC COMPOUNDS; ORGANIC NITROGEN COMPOUNDS
Optional Information
- Notes
- © 2018 Elsevier Ltd. All rights reserved.