Published December 1, 2006 | Version v1
Journal article

Monitored Drift Tubes aging under intensive gamma irradiation

  • 1. Dipartimento di Fisica, Universita degli Studi della Calabria and INFN, Cosenza (Italy)
  • 2. Dipartimento di Fisica, Universita Roma Tre and INFN Sezione di Roma III, Via della Vasca Navale, 84, I-00146 Rome (Italy)

Description

The Monitored Drift Tubes (MDTs) are the key elements for precision tracking of the ATLAS muon spectrometer. In the era of LHC and forecasting an upgrade for SLHC it is crucial to test the detector robustness in the harsh background environment. Under LHC normal operation the expected total count rate is about 500Hz/cm2 for the innermost MDTs, while SLHC can reach fluxes 10 times higher. For a gas gain of 2x104, the overall accumulated charge can be as high as 6C/cm/wire, which the MDTs must be able to withstand in 10 years of SLHC operation. In this paper, results of aging studies performed by irradiating two test detectors with photons from high intensity 60Co source at the ENEA Casaccia Calliope facility are summarized

Additional details

Identifiers

DOI
10.1016/j.nima.2006.08.059;
PII
S0168-9002(06)01385-4;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
568
Journal Issue
2
Journal Page Range
p. 624-633
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.