Point Lepreau Generating Station flux detector replacement coordination and planning
Creators
- 1. New Brunswick Electric Power Commission, Point Lepreau, NB (Canada). Point Lepreau Generating Station
Description
This paper gives an overview of the planning effort to replace the 26 vertical and seven horizontal flux detectors at Point Lepreau Generating Station during the 1992 annual outage. It discusses the strategy used for outage preparation, outage control, and how the flux detector replacement program was managed within the outage. 3 refs
Additional details
Publishing Information
- ISBN
- 0-919784-28-3
- Imprint Title
- The 2nd international conference on CANDU maintenance. Proceedings
- Imprint Pagination
- 2 v.
- Journal Page Range
- p. 475-482.
- Report number
- INIS-mf--14642
Conference
- Title
- Canadian Nuclear Society 2. international conference on CANDU maintenance.
- Dates
- 22-24 Nov 1992.
- Place
- Toronto, ON (Canada).
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 27002312
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- IN CORE INSTRUMENTS; PLANNING; POINT LEPREAU-1 REACTOR; REACTOR MAINTENANCE; RETROFITTING; SELF-POWERED NEUTRON DETECTORS
- Descriptors DEC
- CANDU TYPE REACTORS; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; MAINTENANCE; MEASURING INSTRUMENTS; NATURAL URANIUM REACTORS; NEUTRON DETECTORS; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; RADIATION DETECTORS; REACTORS; SELF-POWERED DETECTORS; THERMAL REACTORS
Optional Information
- Notes
- Imprint:Pages are numbered 425-864 plus appendix A 15 p.