Published October 15, 2010 | Version v1
Journal article

The Results of Recent MICE Superconducting Spectrometer Solenoid Test

Description

The MICE spectrometer solenoid magnets will be the first magnets to be installed within the MICE cooling channel. The MICE spectrometer solenoids may be the largest magnets that have been cooled using small two stage coolers. During the previous test of this magnet, the cooler first stage temperatures were too high. The causes of some of the extra first stage heat load has been identified and corrected. The rebuilt magnet had a single stage GM cooler in addition to the three pulse tube coolers. The added cooler reduces the temperature of the top of the HTS leads, the shield and of the first stage of the pulse tube coolers.

Availability note (English)

Available from OSTI as DE01000047; PURL: https://www.osti.gov/servlets/purl/1000047-hG2VAA/

Additional details

Publishing Information

Journal Title
IEEE Transactions on Applied Superconductivity (Print)
Journal Volume
21
Journal Issue
3
Journal Page Range
p. 4
ISSN
1051-8223

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
42009688
Subject category
S42: ENGINEERING;
Descriptors DEI
HEAT EXCHANGERS; MAGNETS; MICE; SHIELDS; SOLENOIDS; SPECTROMETERS
Descriptors DEC
ANIMALS; ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; MAMMALS; MEASURING INSTRUMENTS; RODENTS; VERTEBRATES