Published September 7, 2020 | Version v1
Journal article

Accurate 3D-dose-based generation of MLC segments for robotic radiotherapy

  • 1. Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands)

Description

Radiotherapy treatment planning requires accurate modeling of the delivered patient dose, including radiation scatter effects, multi-leaf collimator (MLC) leaf transmission, interleaf-leakage, etc. In fluence map optimization (FMO), a simple dose model is used to first generate an intermediate plan based on pencil-beams. In a second step (segmentation phase), this intermediate plan is then converted into a deliverable treatment plan with MLC segments. In this paper, we investigate novel approaches for the use of a clinical dose engine (CDE) for segmentation of FMO plans in robotic radiotherapy. Segments are sequentially added to the plan. Generation of each next segment is based on the total 3D dose distribution, resulting from already selected segments and the desired FMO dose, considering all treatment beams as candidates for delivery of the new segment. Three versions of the segmentation algorithm were investigated with differences in the integration of the CDE. The combined use of pencil-beams and segments in a segmentation method is non-trivial. Therefore, new methods were developed for the use of segment doses calculated with the CDE in combination with pencil-beams, used for the selection of new segments. For 20 patients with prostate cancer and 12 with liver cancer, segmented plans were compared with FMO plans. All three versions of the proposed segmentation algorithm could well mimic FMO dose distributions. Segmentation with a fully integrated CDE provided the best plan quality and lowest numbers of monitor units and segments at the cost of increased calculation time. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6560/ab97e7

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
65
Journal Issue
17
Journal Page Range
[13 p.]
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52081315
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ALGORITHMS; COLLIMATORS; LIVER; NEOPLASMS; OPTIMIZATION; PATIENTS; PROSTATE; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; SIMULATION; THERAPEUTIC DOSES
Descriptors DEC
BODY; DIGESTIVE SYSTEM; DISEASES; DOSES; GLANDS; MALE GENITALS; MATHEMATICAL LOGIC; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY