Verification of dose distribution in high-dose-rate brachytherapy using a nanoclay-based radio-fluorogenic gel dosimeter
Creators
- 1. School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa (Japan)
- 2. School of Science, Kitasato University, Sagamihara, Kanagawa (Japan)
- 3. Faculty of Health Sciences, Hiroshima International University, Higashi-Hiroshima, Hiroshima (Japan)
- 4. Yokohama City Minato Red Cross Hospital, Yokohama, Kanagawa (Japan)
- 5. Proton Medical Research Center, University of Tsukuba Hospital, Tsukuba, Ibaraki (Japan)
Description
Dose distributions have become more complex with the introduction of image-guided brachytherapy in high-dose-rate (HDR) brachytherapy treatments. Therefore, to correctly execute HDR, conducting a quality assurance programme for the remote after-loading system and verifying the dose distribution in the patient treatment plan are necessary. The characteristics of the dose distribution of HDR brachytherapy are that the dose is high near the source and rapidly drops when the distance from the source increases. Therefore, a measurement tool corresponding to the characteristic is required. In this study, using an Iridium-192 (Ir-192) source, we evaluated the basic characteristics of a nanoclay-based radio-fluorogenic gel (NC-RFG) dosimeter that is a fluorescent gel dosimeter using dihydrorhodamine 123 hydrochloride as a fluorescent probe. The two-dimensional dose distribution measurements were performed at multiple source positions to simulate a clinical plan. Fluorescence images of the irradiated NC-RFG were obtained at a high resolution (0.04 mm pixel–1) using a gel scanner with excitation at 465 nm. Good linearity was confirmed up to a dose range of 100 Gy without dose rate dependence. The dose distribution measurement at the five-point source position showed good agreement with the treatment planning system calculation. The pass ratio by gamma analysis was 92.1% with a 2%/1 mm criterion. The NC-RFG dosimeter demonstrates to have the potential of being a useful tool for quality assurance of the dose distribution delivered by HDR brachytherapy. Moreover, compared with conventional gel dosimeters such as polymer gel and Fricke gel dosimeters it solves the problems of diffusion, dose rate dependence and inhibition of oxygen-induced reactions. Furthermore, it facilitates dose data to be read in a short time after irradiation, which is useful for clinical use. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-6560/ab98d2Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 65
- Journal Issue
- 17
- Journal Page Range
- [12 p.]
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52081312
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRACHYTHERAPY; DOSE RATES; DOSEMETERS; FLUORESCENCE; IMAGES; IRIDIUM 192; IRRADIATION; POINT SOURCES; QUALITY ASSURANCE; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; VERIFICATION
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; DAYS LIVING RADIOISOTOPES; DOSES; ELECTRON CAPTURE RADIOISOTOPES; EMISSION; HEAVY NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; IRIDIUM ISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LUMINESCENCE; MANAGEMENT; MEASURING INSTRUMENTS; MEDICINE; MINUTES LIVING RADIOISOTOPES; NUCLEAR MEDICINE; NUCLEI; ODD-ODD NUCLEI; PHOTON EMISSION; QUALITY MANAGEMENT; RADIATION SOURCES; RADIOISOTOPES; RADIOLOGY; RADIOTHERAPY; THERAPY; YEARS LIVING RADIOISOTOPES