Published December 1976
| Version v1
Journal article
Electron temperature measurement in JIPP-Ib stellarator by the method of time history
- 1. Nagoya Univ. (Japan). Inst. of Plasma Physics
Description
The time variation of the line emission of the impurities in the vacuum-ultraviolet spectral range is measured. With the use of experimental data, the electron temperature of the low β plasma confined in JIPP-Ib stellarator has been determined by the method of time history. The helium plasma produced by the ohmically heating current is used. The determined electron temperature is around 120 eV at 0.8 ms after the start of discharge. The results of the simulation based on the model introducing the effect of inhomogeneity show that the electron temperature determined by this method corresponds to the temperature at the plasma center. (auth.)
Additional details
Identifiers
- DOI
- 10.1143/jjap.15.2403;
Publishing Information
- Journal Title
- Japanese Journal of Applied Physics
- Journal Volume
- 15
- Journal Issue
- 12
- Series
- Jpn. J. Appl. Phys.
- Journal Page Range
- 2403-2408
- ISSN
- 0021-4922
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 8331553
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CONFINEMENT; ELECTRON TEMPERATURE; IMPURITIES; JIPP STELLARATOR; LOW-BETA PLASMA; SPECTROMETERS; SPECTROSCOPY; ULTRAVIOLET SPECTRA
- Descriptors DEC
- CLOSED PLASMA DEVICES; MEASURING INSTRUMENTS; PLASMA; SPECTRA; STELLARATORS; THERMONUCLEAR DEVICES