Description

The LOw-Frequency ARray (LOFAR) telescope measures radio emission from air showers. In order to interpret the data, an absolute, frequency dependent calibration is required. Due to a growing need for a better understanding of the measured frequency spectrum, we revisit the calibration of the LOFAR antennas in the range of 30—80 MHz. Using the galactic radio emission and a detailed model of the LOFAR signal chain, we find a calibration that provides an absolute energy scale and allows us to study frequency dependent features in measured air shower signals.

Availability note (English)

Available from https://www.epj-conferences.org/articles/epjconf/pdf/2019/21/epjconf_arena2018_04006.pdf; https://doaj.org/article/5090df70a53b48e2969187627874cca7

Additional details

Publishing Information

Journal Title
EPJ. Web of Conferences
Journal Volume
216
Journal Page Range
vp.
ISSN
2100-014X

Conference

Title
8. International Conference on Acoustic and Radio EeV Neutrino Detection Activities
Acronym
ARENA 2018
Dates
12-15 Jun 2018
Place
Catania (Italy)

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
53095690
Subject category
S79: ASTROPHYSICS, COSMOLOGY AND ASTRONOMY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANTENNAS; CALIBRATION; CASCADE SHOWERS; EMISSION; FREQUENCY DEPENDENCE; MHZ RANGE; SIGNALS; SPECTRA; TELESCOPES
Descriptors DEC
ELECTRICAL EQUIPMENT; EQUIPMENT; FREQUENCY RANGE; SHOWERS