Published December 2018 | Version v1
Journal article

An in silico comparative dosimetric study of postmastectomy locoregional irradiation using intensity-modulated vs 3-dimensional conventional radiotherapy

  • 1. Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi (India)

Description

An in silico dosimetric evaluation of intensity-modulated radiation therapy (IMRT) vs 3-dimensional conventional radiation therapy (3D-CRT) treatment plans in postmastectomy radiation therapy (PMRT) to the chest wall and regional lymphatics was conducted. Twenty-five consecutive patients with breast cancer referred for locoregional PMRT, stages T2-4 with N1-3, were planned to receive 50 Gy in 25 fractions with IMRT. Additionally, a 3D-CRT plan was generated using identical contours for the clinical target volumes (CTV), planning target volumes (PTV), and organs at risk (OAR). Treatment plans were assessed using dose-volume histogram (DVH) parameters of D98, D95, D50, D2, and homogeneity index for individual CTVs and PTVs. OARs evaluated were ipsilateral and contralateral lungs, heart, spinal cord, and opposite breast. Most DVH parameters pertaining to CTVs and PTVs significantly favored IMRT. V20 for ipsilateral and contralateral lungs, D33 of heart and maximum dose to spinal cord favored IMRT (all p vs 2.0 ± 1.0 Gy, p < 0.001). Thus, except for the mean dose to the opposite breast, the compliance to DVH constraints applied to PTV and OARs were significantly better with IMRT. At a median follow-up of 76 months (7-91), none had locoregional failure or pulmonary or cardiac morbidity. For PMRT, requiring comprehensive irradiation to both chest wall and regional lymphatics, IMRT offers superior dosimetric advantages over 3D-CRT. This was also corroborated by long-term outcomes in these patients treated with IMRT.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.meddos.2017.12.001

Additional details

Identifiers

DOI
10.1016/j.meddos.2017.12.001;
PII
S095839471730136X;

Publishing Information

Journal Title
Medical Dosimetry
Journal Volume
43
Journal Issue
4
Journal Page Range
p. 370-376
ISSN
0958-3947

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
50069261
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CHEST; DOSIMETRY; HEART; LUNGS; MAMMARY GLANDS; NEOPLASMS; PATIENTS; PLANNING; RADIATION DOSES; RADIOTHERAPY; SPINAL CORD; THREE-DIMENSIONAL CALCULATIONS
Descriptors DEC
BODY; CARDIOVASCULAR SYSTEM; CENTRAL NERVOUS SYSTEM; DISEASES; DOSES; GLANDS; MEDICINE; NERVOUS SYSTEM; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.