Published 2006 | Version v1
Journal article

Mass distribution of fission fragments using SSNTDs based image analysis system

  • 1. Radiation Safety Systems Div., Bhabha Atomic Research Centre, Mumbai (India)

Description

Lexan polycarbonate track detector was used to obtain mass distribution of fission fragments from 252Cf planchette source, Normally, if the fission fragments are incident perpendicular to the lexan surface, the diameter of heavy fragment is greater than that of lighter fragment. In practical problems fission fragments are incident on the detector at all angles. So, in the present experiment, lexan detector was exposed to 252Cf planchette source in 2π geometry. Fission fragments were incident on the detector with various angles. So the projected fission track length for fission fragment of same energy is different because of different angle of incidence. Image analysis software was used to measure the projected track length. But the problem is that for fission fragment having greater angle of incidence the entire track length is not focused on the surface. So reduced track length is measured. This problem is solved by taking two images, one at the surface and one at the tip of track and then overlapping both the images using image analysis software. The projected track length and the depth of the track were used to get the angle of incidence. Fission track lengths were measured for same angle of incidence. In all 500 track lengths were measured and plot for mass distribution for fission fragment was obtained.(author)

Additional details

Publishing Information

Journal Title
Chemical and Environmental Research
Journal Volume
15
Journal Issue
3-4
Journal Page Range
p. 334-337
ISSN
0971-2151

Conference

Title
14. national symposium on solid state nuclear track detectors and their applications
Acronym
SSNTDs 2005
Dates
10-12 Nov 2005
Place
Aligarh (India)

Optional Information

Notes
2 refs., 5 figs., 1 tab.