Background and purpose: A dosimetric intercomparison of brachytherapy remote afterloading units in Ireland, Scotland and the North of England has been carried out involving 9 radiotherapy centres, and sampling 5 HDR and 6 LDR units. Materials and methods: Absolute calibrations have been performed in air on both HDR and LDR sources. The results are expressed in terms of a ratio of local to calibrated value. Frequency distributions were obtained for the multi-source LDR units by individually measuring each source. Using these distributions the effect of non-uniform source strength on the dose rate at Manchester point A was assessed for a typical clinical brachytherapy insertion for carcinoma of the cervix. Both frequency and dose rate distribution curves were modeled using normal statistics and characterised in terms of the mean (μ) and standard deviation (σ). Results: Evaluation of the HDR units indicated a mean ratio of 1.008 (±0.01) while for LDR the mean ratio was 0.997 (±0.02). The LDR frequency distributions demonstrated a variation of σ values extending from 1.4 to 3.0% of μ. It was shown that this non-uniformity in source strength introduced an uncertainty in the treatment planning process of between 0.8 and 1.8% when compared to the assumption of uniform source strength. Conclusions: The results of this intercomparison indicate dosimetric consistency between centres for both LDR and HDR units. The distribution of LDR source strengths were within expected limits and the resultant dose rate distributions were considered clinically acceptable

Additional details

Identifiers

DOI
10.1016/j.radonc.2004.10.015;
PII
S0167-8140(04)00517-1;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
74
Journal Issue
2
Journal Page Range
p. 149-156
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
37018745
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
AFTERLOADING; BRACHYTHERAPY; CALIBRATION; CARCINOMAS; DOSE RATES; DOSIMETRY; EVALUATION; IRELAND; SAMPLING
Descriptors DEC
DEVELOPED COUNTRIES; DISEASES; EUROPE; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; RADIOLOGY; RADIOTHERAPY; THERAPY; WESTERN EUROPE

Optional Information

Copyright
Copyright (c) 2004 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.