Published June 2001 | Version v1
Journal article

Radiation dose from reentrant electrons

Description

In estimating the crew exposures during an extra vehicular activity (EVA), the contribution of reentrant electrons has always been neglected. Although the flux of these electrons is small compared to the flux of trapped electrons, their energy spectrum extends to several GeV compared to about 7 MeV for trapped electrons. This is also true of splash electrons. Using the measured reentrant electron energy spectra, it is shown that the dose contribution of these electrons to the blood forming organs (BFO) is more than 10 times greater than that from the trapped electrons. The calculations also show that the dose-depth response is a very slowly changing function of depth, and thus adding reasonable amounts of additional shielding would not significantly lower the dose to BFO

Additional details

Identifiers

PII
S1350448700001505;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
33
Journal Issue
3
Journal Page Range
p. 369-372
ISSN
1350-4487
CODEN
RMEAEP

Optional Information

Copyright
Copyright (c) 2001 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.